HP StorageWorks XP24000 Remote Web Console Error Codes, v01 (AE131-96004, June 2007)

Table 27 Error Codes Part Code 1005
Part
Code
Error
Number
Error Message
Recommended Action
Severity
Level
Failure
Level
1005 1002
The specied volume cannot
be
set as a command
device or a component of
aLUSEvolume, because
it is
being used as a
Continuous Access, Business
Copy, Cross-system Copy,
Auto LUN, or XP Snapshot
volume. Select another
volume.
Select another volume.
E
6
1005 1003
You are try
ing to set multiple
paths to t
he
same volume
from one g
roup.
The Conguration
informati
on
has been
already ch
anged.
Please che
ck the settings
and request the setting of the
congura
tion information
again.
E
6
1005
1004
Multiple volumes are
specied to a single port,
group or LUN combination.
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
1005 1005
The following volumes
cannot
be specied
when you change path
congurations:
Volumes that do not exist
Volumes other than top
LUs in expanded LUs
Volumes reserved by
Auto LUN
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
10
05
10
07
Fai
led
to remove the path.
Th
especied path is the last
pa
th
of the volumes used for
Co
ntinuous
Access, Business
C
opy, Cross-system Copy,
A
uto
LUN, or XP Snapshot.
Check the setting.
E
6
1005 1009
The emulation type of the
volumes is not for open
systems, or the volumes are
not mounted. Check the
setting.
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
1005 1010
An error occurred during
SVP processing. If this
problem persists, please call
technical support.
If this problem persists, call
technical supp ort.
E
2
102
HP
StorageWorks XP Remote Web Console for Storage System Messages and Error Codes