HP StorageWorks XP24000 Remote Web Console Error Codes, v01 (AE131-96004, June 2007)
Part
Code
Error
Number
Error Message
Recommended Action
Severity
Level
Failure
Level
3010 505 5
Thereisnovolumetobe
initialized.
A
volume cannot be
initialized when it is:
•
Defined with a path or
paths
•
Used as a LUSE volume
•
Reserved for Auto LUN
•
Paired with another
volume
•
Set as a command
device
•
Used for Volume Security
• Not
read/write-enabled
•
Used as a Pool volume
•
Used as a JNL volume
•
Used as a Remote
Command Device
volume
•
Used as a System Disk
Device volume
Check the content of the
operation.
W
5
3010 5056
Select LDEVs after canceling
the
automatically selected
LDEVs.
Check the content of the
operation.
W
5
3010 505 7
There are not enough LDEVs.
Check
the
content of the
opera
tion.
W
5
3010 5058
Volume Initialize cannot
be
performed because the
number of volumes that can
be
created in the parity
group is exceeded.
Reduce the number of
volumes in the parity group,
then
retry.
W
5
3010 5060
The setting capacity in the
VLL operation is outside
the
setting range. Set the
capacity within the specified
range.
Enter the correct value.
W
5
3010 5061
Set the number of cylinders
used for VLL operation to 50
cylinders or more .
Enter the correct value.
W
5
3010 5062
LDEV Creation failed
because the sp ecified
capacity was invalid.
Enter the correct value.
W
5
3010 5063
The LDEV capacity is not
specified.
Don't c ontain LUSE at the
time of more than one
choice.
W
5
3010 5064
LDEV capacity is not
specified.
Specify LDEV capacity
correctly.
W
5
3010 5065
The number of LDEVs is not
specified.
Specify the number of LDEVs
correctly.
W
5
3010 7 060
An error occurred in the
client logic.
Please call technical
support.
E
2
144
HP