HP StorageWorks XP24000 Remote Web Console Error Codes, v01 (AE131-96004, June 2007)

Part
Code
Error
Number
Error Messag e
Recommended Ac tion
Severity
Level
Failure
Level
6005 8701
Logical Path between the
MCU and the RCU is not
active.
A logical path does not exist
between the MCU and the
RCU. Check the path status
on
RCU Status screen, and
reestablish the paths with
Edit Path.
i
4
6005 8702
The pair status of the M-VOL
is not
valid.
Thetypeofpairstatusisnot
permitted for this operation.
Refresh and check the
screen. If the M-VOL status
permits the operation, retry
the operation.
i
4
6005 8703
The specied number
of Paths islessthan the
Minimum number of Paths
on
RCU Option screen.
The number
of pathsisless
than the mi
nimum
number
specied o
nthe RCUOption
screen. C
heck the number
of
paths,
establish the
minimum n
umber of paths,
and
retr
ythe operation.
i
4
6005 8704
The specied number of
paths islessthan the
minimum number of paths
on
the RCU option screen
due to a communication
error between the MCU
and
the RCU, or the device
emulation type of the
R-VOL is not supported by
Continuous Access via serial
interface.
Please check the paths
status on the
RCU Status
screen, and reestablish
the paths on the Edit Path
screen. Please see th e
OPENPLATFORM SECTION
in the maintenance manual
to
conrm whether the
device emulation type of
the R-VOL is supported by
Continuous Access via serial
interface.
W 4
6005 8705
The path could not
be deleted due to a
communication error
between MCU and RCU.
Either a communication
error occurred between
the MCU and the RCU,
or the
CHA has become
blocked. Please call
technical support.
W 4
6005 8706
Parameter specied
by Continuous Access
operation is invalid.
Ap
arameter specied by
t
he Continuous Access
o
peration is invalid. For
e
xample, the R-VOL that
is
specied could already
be in
use as the R-VOL of
another Continuous Access
pair.
i
4
6005 8708
The pair status of the R-VOL
is not
valid.
Check the pair status for
Continuous Access. If the
requested R-VOL is in a
permissible status, retry the
operation.
i
4
6005 8709
Continuous Access
operation was rejected.
All channel adapters are
not
active for Continuous
Access. Please call technical
support.
E
4
XP24000 Remote Web Console Error Codes
197