6005 8731
The existing logical
addresses are not equal.
The logical addresses of all
existing paths are not the
same. Delete the RCU, then
re-add it, using the same
logicaladdressasother
existing paths.
i
4
6005 8732
ToomanySSIDs (OnlyFour
SSIDs are allowed).
The maximum number
of
SSIDs (four) has been
entered. Verify that the
SSIDs are valid, delete
one
or more, then retry the
operation.
E
4
6005 8733
TheFibre-RemoteCopy
function is not installed in
the
specied MCU.
Please ins
tall
the program
product ke
yinthe MCU.
i
4
6005 8734
TheFibre-RemoteCopy
function is not installed in
the
specied RCU.
Please install the program
product key in the RCU.
i
4
6005 8735
Invalid RCU serial number,
SSID, Link Address or
Controller ID.
Check the serial number,
SSID and link address
of the RCU, and set the
correct value. Then retry
the
operation. If the same
error occurs, call technical
support.
E
4
6005 8736
The specied RCU or SSID
contains some Continuous
Access volume pairs.
Delet
eall Continuous
Acces
s
volume pairs of the
spec
ied RCU or SSID, and
retr
ythe operation.
i
4
6005 873 7
An internal error occurred.
Please call technical
support.
E
4
6005 8738
Continuous Access is not
supported under the MCU
Controller emulation type.
The emulation type of the
MCU does not support
Continuous Access. To use
Continuous Access, Please
call
technical support.
i
4
6
005
8
739
NVS status of MCU is not
active.
Th
eMCU NVSstatus
sp
ecied by the host is not
a
ctive. Set the NVS to on
f
or
the MCU , using any
a
ttached host, then retry the
operation.
i
4
6005 8740
NVS status of RCU is not
active.
The RCU NVS status
specied by the host is not
active. Use any attached
host to set the NVS to on
for the MCU, then retry the
operation.
i
4
6005
87 41
The logical paths between
the
MCU and RCU a re not
established.
Check the path status
between the MCU and the
RCU.
i
4
6005
87 42
Pinned track(s) exists on the
M-VOL.
Check the status of the
M-VOL tracks, and clear the
pinned tracks.
W 4
200
HP