HP StorageWorks XP24000 Remote Web Console Error Codes, v01 (AE131-96004, June 2007)
Part
Code
Error
Number
Error Message
Recommended Action
Severity
Level
Failure
Level
6005 8795
The operation failed
because the sp ecified
M-VOL was one of the
following:
•
AT-VOL of
ShadowImage for
Mainframe an d not
in
the Split pair(PSUS)
status.
• An
S-VOL of Business
Copy and not in the Split
pair (PSUS) status.
•
Areserved volume
of
ShadowImage for
Mainframe or Business
Copy.
•
Avolumeinthe
Reverse Copy status
of
ShadowImage for
Mainframe or Business
Copy.
•
AT-VOL of Compatible
FlashCopy .
Check the status of the
specified M-VOL from the
host or the SVP.
i
4
6005 8796
The operation failed
because the specified R-VOL
was one of the following:
•
AT-VOL of
ShadowImage
for Mainframe or
Compatible FlashCopy
• An
S-VOL of Business
Copy.
•
Areserved volume
of
ShadowImage for
Mainframe or Business
Copy.
•
Avolumeinthe
Reverse Copy status
of
ShadowImage for
Mainframe or Business
Copy.
Check the status of the
specified R-VOL from the
host or the SVP.
i
4
6005 8797
The M-VOL is the
ShadowImage for
Mainframe/Business
Copy/Compatible
FlashCopy T-VOL, one
S-VOL must be paired with
one
T-VOL.
Check the status of the
specified M-VOL from the
host or the SVP.
i
4
6005 8798
The MCU is already
used for ShadowImage
for Mainframe/Business
Copy/Compatible
FlashCopy .
The Add Pair operation
failed because the MCU
is
already being used for
Business Copy/Compatible
FlashCopy. Verify the status
of the MCU and retry the
operation.
i
4
6005 8799
The M-VOL is already in use
for Auto LUN.
Verify the status of the
specified M-VOL.
E
4
206
HP
StorageWorks XP Remote Web Console for Storage System Messages and Error Codes