HP StorageWorks XP24000 Remote Web Console Error Codes, v01 (AE131-96004, June 2007)

Part
Code
Error
Number
Error Messag e
Recommended Ac tion
Severity
Level
Failure
Level
6005
89 43
The specied volume
or other
volume(s) of
thesamegroup in the
RCU is being changed to
Simplex/Suspend status.
Retry the operation a few
minutes later.
Refresh the window a few
minutes later and check
the status of the specied
volume and other volume(s)
of the same group in the
RCU. If it is possible to
perform operations on
the volume(s), retry the
operation.
i
4
6005
89 44
The specied R-VOL is not
available according to
the
attribute of the R-VOL
changed by Data Retention
Utility.
Check the status of the
specied R-VOL.
i
4
6005
89 45
At least one of the following
is
invalid:
M-VOL parameters (CU
number, Port, GID, LUN)
SSID or CU number of
the
RCU
R-VOL parameters (Por t,
GID, LUN)
Verify whether the
parameters of M-VOL,
for example, CU number,
port, GID and LUN, are
supported with the RCU
microcode program version
or
not. V
erify whether the
SSID an
d
CU number of
RCU and
the parameters of
R-VOL
,
for example, Port,
GID
an
dLUN,are correct
or
not
.
And then, retry the
oper
ationwiththe correct
para
meters.
W 4
6005 8947
The external volume that
is mapped to an internal
volume is c onnected to the
port.
Release the setting of the
external volume, and retry
the operation.
i
4
6005 8948
The specied port is
receiving I/O requests.
Stop I/O operations, and
retry .
i
4
60
05
89 49
An internal error occurred.
Ple
ase call technical
su
pport.
E
4
6005 8950
An internal error occurred.
Please call technical
support.
E
4
6005 897 3
Failed to create a pair,
because the specied R-VOL
is
used for Cross-system
Copy.
Check the status of the
specied R-VOL.
i
4
6005
8974
Failed to create a pair,
because the specied
M-VOL is path-dened from
the
iSCSI port.
Check the status of the
specied M-VOL.
i
4
6005 8975
Failed to create a pair,
because the specied R-VOL
is path-dened from the
iSC SI port.
Check the status of the
specied R-VOL.
i
4
6005 8976
A pair cannot be created,
because the specied
M-VOL is an external
volume.
Check the status of the
specied M-VOL.
i
4
XP24000 Remote Web Console Error Codes