HP StorageWorks XP24000 Remote Web Console Error Codes, v01 (AE131-96004, June 2007)

Part
Code
Error
Number
Error Messag e
Recommended Ac tion
Severity
Level
Failure
Level
6505 8710
The pair status of the
specied data volume is
incorrect.
Please refresh the window
and
check the pair status of
the pair. If the pair status
can be manipulated, retry
the operation.
W
0
6505 8711
The specied parameter is
incorrect.
Check the port number, ID,
and LUN of the storage
system.
i
4
6505 8712
The operation was rejected
due to a FREEZE state.
If you are per
forming a
path operat
ion, retry the
operation a
fter the FREEZE
status is
re
leased.
If
you are pe
rforming a pair
operation
,check theDKC
status, wa
it
until the SCP
time
elap
ses, then retry the
operatio
n.
E
4
6505 8713
The port group already
exists on the specied por t.
Please exchange the port
type af ter deleting the group
setting.
E
4
6505
8714
An internal error occurred.
Please call technical
support.
E
4
6505 8715
The number of paths is
incorrect.
Ensure
that the
number
of
path
sis correct, then
retry t
he
operation. If
the pr
oblem persists, call
techn
ical support.
E
4
6505 8719
Theserialnumberorthe
controller ID of the re mote
subsystemisincorrect.
Check the serial number
and
the controller ID of this
remote storage system and
already registered remote
storage systems, then specify
the correct values.
If the
specied values
are correct, check the
cable
connection of the
remote storage system. If
the problem persists, call
technical support.
E
4
6505 8720
The number of registered
remote subsystems already
reached the maximum (that
is, 64).
Reduce the number of
registered remote storage
systems, then retry the
operation.
i
4
6505 8721
Path creation has not
nished yet.
Check the path connections
between the local and the
remote storage sy stems, then
retry the operation.
E
4
6505 8722
Path creation failed.
Check the path connections
between the local and the
remote storage sy stems, then
retry the operation.
E
4
XP24000 Remote Web Console Error Codes
237