HP StorageWorks XP24000 Remote Web Console Error Codes, v01 (AE131-96004, June 2007)

Part
Code
Error
Number
Error Messag e
Recommended Ac tion
Severity
Level
Failure
Level
6505
58 7 04
The Add Pair (Paircre ate)
operation to get ready for
Delta resync failed because
the
status of the volumes
was one of the following:
The P-VOL for Continuous
Access Synchronous and
the
primary data volume
for Continuous Access
Journal are different.
The M -VOL for
TrueCopy for Mainframe
Synchronous and the
primary data volume for
Universal Replicator for
Mainframe are different.
Check the status of the data
volumes in the Continuous
Access, TrueCopy f or
Mainframe, Continuous
Access Journal or the
Universal Replicator for
Mainframe window.
W
0
6505 587 05
The Delta resync operation
failed. The specied
secondary data volume
should meet the following
requirements.
The specied volume is a
secondary data volume
of
another mirror.
The pair status of the
specied volume is
PSUS, PSUE, Suspend,
PAIR or Duplex.
Check the status of the
specied secondary data
volume.
W
0
6505 587 0 7
The Add Pair (Paircre ate)
operation or the Resume Pair
(Pairresync) operation failed
because the status of the
specied secondary data
volume was Not Ready.
Check the status of the
specied secondary data
volume.
W
0
6505 587 08
The Add Pair (Paircre ate)
operation to get ready for
Delta resync failed, or the
recovery to the status ready
for Delta resync failed. If
the same problem persists
despite retrying, please call
technical support.
If thesameproblem
persists despite retrying,
call
technical support.
W
0
6505 58716
The licensed capacit y
of
Continuous Access or
TrueCopy for Mainframe on
the
RCU is insufcient.
Check the licensed capacity
of this
program product
andthe relatedprogram
products.
The related program
products are:
Continuous Access or
TrueCopy for Mainframe
Continuous Access
Journal or Universal
Replicator for Mainframe
Check the licensed capacity
of this program product
andthe relatedprogram
products.
See the user's guides of
Continuous Access or
TrueCopy for Mainframe
for details on the licensed
capacities.
The related program
products are:
Continuous Access or
TrueCopy for Mainframe
Continuous Access
Journal or Universal
Replicator for Mainframe
W
5
XP24000 Remote Web Console Error Codes
271