HP StorageWorks XP24000 Remote Web Console Error Codes, v01 (AE131-96004, June 2007)

Part
Code
Error
Number
Error Message
Recommended Action
Severity
Level
Failure
Level
6610 59112
The CLPR number of the
specied data volume is
different from the CLPR
number of
the data volume
in the
Preview list. In this
operation, please specify
only one C LPR number.
Please specify only the
volume that has the same
CLPR number as th e CLPR
number of the volume in the
Preview list.
W
5
6610 59113
Thereare twoormoreCLPR
numbers for the specied
volume, or y ou tried to
register a volume different
from the CLPR number of
an
existing volume. Two or
more CLPR numbers cannot
exist in one journal group.
Please check the CLPR
number of the specied
volume, and check the CLPR
numbers of any existing
volumes. Be sure the journal
group has only one CLPR
number while specifying a
volume.
W
5
6610 59115
The number of Preview data
may have exceeded the
limit, or too large number of
data is selected.
If there are some Preview
data, check the number.
If it is too
large, clear the
Preview data by clicking
[Apply] and retry t he
operation. If there is no
Preview data, too large
number
of
data is selected.
Reduc
ethe number of data
and
re
try the operation.
W
5
6610 59116
The specied function is not
supported by the current
microcode version.
Check the microcode
version of the DKCMAIN,
then
call technical support.
W
0
6610 59119
The current microcode
version does not allow you
to change options for a
journal group in the Active
status.
Check the microcode
version of the DKCMAIN,
then
call technical support.
W
0
6610 59150
The
current microcode
ve
rsion of DKCMAIN
do
es not support Add Pair
(P
aircreate) operations,
R
esume
Pair operations,
a
nd
Change Pair Option
o
perations using the
emulation type of the
specied volume.
Check the microcode
versionofDKCMAIN. Ifyou
want use other emulation
types, call technical support
and
update the microcode
version of DKCMAIN.
W
0
6610 59151
The current microcode
version of DKCMAIN only
supports OPEN-V as the
emulation type of a journal
volume.
To useamainframevolume
as a
journal volume, call
technical support and
update the microcode
version of DKCMAIN.
W
0
6610 59152
There are two or more kinds
of
emulation types that
cannot
be combined, in the
specied volume. Or you
triedtoaddavolumewhich
cannot
be combined with
the
emulation type of the
existing volume.
Check th e emulation t ype of
the
specied volume.
W
0
292
HP
StorageWorks XP Remote Web Console for Storage System Messages and Error Codes