HP StorageWorks XP24000 Remote Web Console Error Codes, v01 (AE131-96004, June 2007)

Part
Code
Error
Number
Error Messag e
Recommended Ac tion
Severity
Level
Failure
Level
0003 1192
When a path is dened from
an
iSCSI p ort to a volume,
thevolumecannotbe
congured as a command
device. Also, paths cannot
be
dened from iSCSI ports
to command devices.
Please correct the settings,
then retry.
E
6
0003 1193
You cannot add paths to
Continuous Access/Business
Copy/Cross-system Copy
pair volumes.
Please correct the settings,
then retry.
E
6
0003
1194
No informat
ion can be
changed ab
out this external
port becau
se
the port has
an
extern
al
volume.
Please correct the settings,
then retry.
E
6
0003 1195
The specied volume(s) are
used as a command device.
Please correct the settings,
then retry.
E
6
0003 1196
You cannot create a LUSE
volume by concatenating
LUs and Cross-system Copy
LUs.
Please correct the settings,
then retry.
E
6
0003 1197
You cann
ot
set high-speed
mode to a
package
includ
ing
an external
port.
Please c
orrect the settings,
then re
try.
E
6
0003 1198
Since a path is dened to
aCross-systemCopyLU,
you cannot set high-speed
mode.
Please correct the settings,
then retry.
E
6
0003 1199
When dening paths from
iSCSI ports, you can only
dene paths to open-systems
volumes.
Please correct the settings,
then retry.
E
6
0003 1201
The s
election of High Speed
mode/MIX mode is invalid.
The specied port cannot
be
changed to High Speed
mod
e/MIX mode.
Change the parameter to a
path
where the High Speed
mod
e/MIX mode can be
set
,
then retry the operation.
E
6
0003 1203
High Speed mode/MIX
mode
was specied.
However, there are
addresses to which High
Speed mode/MIX mode
cannot
be set in the Fibre
Addresses of the spec ied
ports.
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
0003 1204
High Speed mode/MIX
mode
was specied.
However, there are
topologies to which
High Speed mode/MIX
mode
cannot be set in the
topologies of the specied
ports.
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
XP24000 Remote Web Console Error Codes