0003 1350
You c ould not add the path
to the initiator or external
port.
To add a path, change the
attribute of the specied port
to
Target or RCU Target.
E
6
0003 1351
The high-speed or
initiator/external mix
mode
cannot be set to the
specied port because of
the
attribute of the port.
Cannot set to high-speed
mode
because the
port attributes are
mixed, or cannot set to
internal/external mix mode
because the combination of
port attributes is different.
Check the port attributes,
then
retry the operation.
E
6
0003 1352
Logical paths remain on
the
Fibre-MCU port. This
operation may cause a fatal
damage to the logical paths.
Please stop this operation.
If
you want to continue this
operation, please remove
the
logical paths from the
MCU
por
t
rst.
Since the por t you are trying
to set
is
for Fibre Continuous
Access,
you must delete the
logical
path, then retry the
port se
tting.
E
6
0003 1353
S-VOLs remain on the
Fibre-RCU port. This
operation may cause a
fatal damage to S -VOLs.
Please stop this operation.
If
you want to continue this
operation, please remove
the S-VOLsfromthe RCU
port rst.
Since the por t you are trying
to set
is for Fibre Continuous
Access, you must delete the
S-VOL logical path which is
set
to RCU Target, then retry
the
port setting.
E
6
0003
1354
You could not register the
WWN to the initiator or
external por t.
To register the WWN,
change the attribute of the
specied port to Target or
RCU Target.
E
6
0
003
1
355
You could not change the
host mode of the host group
that you connected to the
initiatororexternalport.
To change the host mode,
c
hange
the at tribute of the
specied port to Target or
RCU Target.
E
6
0003 1356
You could not add the host
group to the initiator or
external por t.
To add the host group,
change the attribute of the
specied port to Target or
RCU Target.
E
6
0003 1357
S-VOLs remain on the
Fibre-RCU port. This
operation may cause a
fatal damage to the S-VOLs.
Please stop this operation.
If
you want to continue this
operation, please remove
the S-VOLsfromthe RCU
port rst.
The specied Por t is for Fibre
Continuous Access. Please
delete a logical path, then
retry the operation.
E
6
0003 1358
HP StorageWorks XP Cache
Residency Manager cannot
be set
to the specied
volume because the IO
Suppression mode is set to
Enable.
Disable the IO Suppression
mode of this volume, then
retry the operation, or
remove thevolumefromthe
volumes to be set.
E
2
34
HP