HP StorageWorks HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Novell NetWare Release Notes (AA-RV1NA-TE, March 2005)

ACS Enhancements and Fixes
15HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Novell
NetWare Release Notes
8.
REINITIALIZE container-name
TURNSAVEOFF
Disables the option to save configuration
information for devices that were initialized
with the
SAVE_CONFIGURATION
switch.
9.
REINITIALIZE container-name
SPECIAL_FUNCTION_ONE=INFO
Directs the controller to examine
RAID5-only containers and report:
Which devices, if any, have metadata
attributes that are inconsistent as a
result of sparing operations to RAID5
sets while ACS V8.7-2 or later was
running.
Which devices have partition flags, no
partition flags, or inconsistencies on
associated containers.
Whether attached units exist, if any.
Note: Issuing this command displays
information for only those containers or
units that are online or assigned to the
controller from which the command is
issued. If you issue this switch with the
REINITIALIZE
container-name
command for a RAIDset on another
controller, the following message displays:
Error 9620: Information not
available on this controller.
Enter command on other
controller.
Table 1: New CLI Commands and Switches (Continued)
Item CLI Command or Switch Description and Background