HP StorageWorks Command Console V2.5 User Guide (AA-RV1UA-TE, March 2005)

Table Of Contents
Interpreting Agent Email Messages
65Command Console V2.5 User Guide
The details about the failure of the LUN follow in parentheses, in the format:
virtual_disk:state
where virtual_disk is the unit number of the virtual disk and state is any of the
following:
0—Good.
1—Reduced.
2—Reconstructing.
3—Failed.
In this example, logical unit D100 failed.
In most cases, the RaidManager sends at least two consecutive email messages.
The first message is always in the form:
---------------
From RaidManager Tue Oct 6 16:09:37 1998
Date: Tue, 6 Oct 1998 16:09:37 -0500 (EST)
From: RaidManager
This is an automatic message from your StorageWorks
RAID Agent, steamd. The following message was just received.
Please check your syslog files and RAID box!
Hostname: Suncity
WARNING: - A RAID system change has been detected: Suncity HSG80
OVRL=1 (SP_MONITOR: MonitorSubsys)
End Of Automatic Message.
-------------
The text of the second message will be similar to the following (depending on the
error):
---------
From RaidManager Tue Oct 6 16:09:37 1998
Date: Tue, 6 Oct 1998 16:09:37 -0500 (EST)
From: RaidManager
This is an automatic message from your StorageWorks
RAID Agent, steamd. The following message was just received.
Please check your syslog files and RAID box!
Hostname: Suncity
WARNING: - Suncity HSG80 12000000000 HSG80 disks(disk10200:1
disk10300:2) (SP_MONITOR: MonitorSubsys)
End Of Automatic Message.
-------------