HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide (AA-RV1HA-TE, March 2005)

FC Configuration Procedures
160 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
Configuration Options
There are multiple options that allow you to configure your system.
Changing the CLI Prompt
To change the CLI prompt, enter a 1- to 16- character string as the new prompt,
according to the following syntax:
SET THIS_CONTROLLER PROMPT = “NEW PROMPT”
If you are configuring dual-redundant controllers, also change the CLI prompt on
the “other controller.” Use the following syntax:
SET OTHER_CONTROLLER PROMPT = “NEW PROMPT”
Note: It is suggested that the prompt name reflect some information about the
controllers. For example, if the subsystem is the third one in a lab, name the top
controller prompt, LAB3A and the bottom controller, LAB3B.
Mirroring Cache
To specify mirrored cache, use the following syntax:
SET THIS MIRRORED_CACHE
Adding Disk Drives
If you add new disk drives to the subsystem, the disk drives must be added to the
controllers’ list of known devices:
To add one new disk drive to the list of known devices, use the following
syntax:
ADD DISK DISKNNNNN P T L
To add several new disk drives to the list of known devices, enter the
following command:
RUN CONFIG
Adding a Disk Drive to the Spareset
The spareset is a collection of spare disk drives that are available to the controller
should it need to replace a failed member of a RAIDset or mirrorset.