HP StorageWorks HSG80 ACS Solution Software V8.8 for Novell NetWare Installation and Configuration Guide (AA-RV1MA-TE, March 2005)

Preparing the Host System
108 HSG80 ACS Solution Software V8.8 for Novell NetWare Installation and Configuration Guide
Note: If you have a Proliant server, ensure that CPQSHD.CDM is later than 2.0.
Logintmo Parameter
load cpqfc.ham logintmo = Number of seconds that the driver
waits for the Enterprise Storage RAID Array to log back in with
the initiator after a loop/link reset
In some cases, Enterprise Storage RAID Array configurations using large caches
took longer during transparent failovers than the driver’s default login timeout of
15 seconds allowed. The command line parameter “LOGINTMO=n” where “n” is
in seconds overrides the 15-second timeout on HSG80 array controller.
Recommended values are from 15 to 30 seconds.
List Devices
1850B1:list devices
0x0001: [V500-A0-D0:0] Compaq 53C876 Slot 0 Port 1 ID 0 COMPAQ BD009122
0x0009: [V502-A2-D0:4] Compaq RA8000 ID 0 LUN 4 (5000-1FE1-0000-3420)
0x000A: [V502-A2-D3:0] Compaq RA8000 ID 3 LUN 0 (5000-1FE1-0000-3420)
0x000B: [V502-A2-D3:11] Compaq RA8000 ID 3 LUN 17 (5000-1FE1-0000-3420)
0x0017: [V025-A4-D1:0] COMPAQ CD-224E rev:9.0B
The list devices command show the Enterprise Storage RAID Array
storagesets and the Worldwide ID on the HSG80 controller that the storageset is
created on. This is useful when configuring multiple arrays. To see the worldwide
ID of the HSG80 controller in the Enterprise Storage RAID Array, use the
command line interface to the HSG80 array controller and type
show this and
look at the NODE_ID.