HP StorageWorks HSG80 ACS Solution Software V8.8 for Novell NetWare Installation and Configuration Guide (AA-RV1MA-TE, March 2005)

FC Configuration Procedures
117HSG80 ACS Solution Software V8.8 for Novell NetWare Installation and Configuration Guide
The node ID is located in the third line of the SHOW THIS result:
HSG80> SHOW THIS
Controller:
HSG80 ZG80900583 Software V8.8, Hardware E11
NODE_ID = 5000-1FE1-0001-3F00
ALLOCATION_CLASS = 0
If the node ID is present, go to step 5.
If the node ID is all zeroes, enter node ID and checksum, which are located on
a sticker on the controller enclosure. Use the following syntax to enter the
node ID:
SET THIS NODE_ID=NNNN-NNNN-NNNN-NNNN nn
Where:NNNN-NNNN-NNNN-NNNN is the node ID, and nn is the checksum.
2. When using a controller that is not new from the factory, enter the following
command to take it out of any failover mode that may have been configured
previously:
SET NOFAILOVER
If the controller did have a failover mode previously set, the CLI may report
an error. Clear the error with this command:
CLEAR_ERRORS CLI
3. Enter the following command to remove any previously configured
connections:
SHOW CONNECTIONS
A list of named connections, if any, opens.
4. Delete these connections by entering the following command:
DELETE !NEWCON01
Repeat the Delete command for each of the listed connections. When
completed, no connection opens.
Configuring Controller Settings
5. Set the SCSI version using the following command syntax:
SET THIS SCSI_VERSION=SCSI-2, or
SET THIS SCSI_VERSION=SCSI-3