HP StorageWorks HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Linux X86 Release Notes (AA-RV1KA-TE, March 2005)

ACS Enhancements and Fixes
16 HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Linux
X86 Release Notes
10.
REINITIALIZE container-name
SPECIAL_FUNCTION_ONE=
PARTITION
Directs the controller to set the partition flag
bits on all devices in a container and
establishes the container as a partitioned
container. This command can only be used
with RAIDset containers.
Caution: Ensure that the container
was previously initialized as a
partitioned container before using
this command. Failure to do so
results in loss of access to
partitioned data.
Note: Issuing the SPECIAL_
FUNCTION_ONE=PARTITION or the
SPECIAL_FUNCTION_ONE=
PARTITION
switch in dual-redundant
controller configurations causes the
container ownership to move to the
controller from which the REINITIALIZE
container-name command was not
issued.
Table 1: New CLI Commands and Switches (Continued)
Item CLI Command or Switch Description and Background