HP StorageWorks HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Linux X86 Release Notes (AA-RV1KA-TE, March 2005)

ACS Enhancements and Fixes
22 HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Linux
X86 Release Notes
Table 3: New FMU Commands and Switches
Item FMU Command or Switch Description
1. SHOW RESERVATIONS ALL
SHOW RESERVATIONS
unit
number
Displays reservations that exist on one or more units.
2. SHOW DEVICE_INFO
unit
SHOW DEVICE_INFO ALL
Displays specific disk information, such as port
number, target number, model ID, firmware version,
model serial numbers, device flags, and metadata
details.
3. SHOW DEVICE_ERRORS
CLEAR DEVICE_ERRORS
Displays device errors and stores a log of events in
the controller non-volatile memory (NVMEM).
4. SHOW LAST ALL Displays pertinent information relative to a controller
crash and can be used by an HP service
representative to help identify the cause of a
controller crash. This command invokes the SHOW
LAST ALL
FULL FMU command.