24. Fibre Channel (FC) switch goes
port INSYNC state to HSG
Previous to this release, resource leaks occurred if a
controller processed PLOGI frames against the rejected
host list while the connection table was locked. The
controller would report that all port conditions were
Good. The FC switches would report as being in the
INSYNC state for connection to one or more HSG
controller ports. Consequently, this condition could not be
cleared through VTDPY. This issue is resolved with this
release.