HP StorageWorks Command Console V2.5 User Guide (AA-RV1UA-TE, March 2005)

Table Of Contents
Interpreting SNMP Traps
122 Command Console V2.5 User Guide
"This variable reports the status for the
Power Supply system in the subsystem."
::= { ssEntry 5 }
ssFanStatus OBJECT-TYPE
SYNTAX INTEGER {
ALL_OK(0),
AT_LEAST_1_FAILURE(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable reports the status for the
FAN system in the subsystem."
::= { ssEntry 6 }
ssCacheBatteryStatus OBJECT-TYPE
SYNTAX INTEGER {
NORMAL_CHARGE(0),
LOW_CHARGE(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable reports the status for the
Cache Battery in the subsystem. This status object is
currently
non-functional but in place for future use."
::= { ssEntry 7 }
ssTemperatureStatus OBJECT-TYPE
SYNTAX INTEGER {
NORMAL(0),
OVER_TEMP_CONDITION(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable reports the status for the
Temperature in the subsystem."
::= { ssEntry 8 }
ssCommStatus OBJECT-TYPE
SYNTAX INTEGER {
NORMAL(0),
COMMUNICATION_FAILURE(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION