HP StorageWorks Command Console V2.5 User Guide (AA-RV1UA-TE, March 2005)

Table Of Contents
Interpreting Agent Email Messages
61Command Console V2.5 User Guide
where cabinet_number is the cabinet ID from 0 to 1, the power-position is the
power supply location (1 or 2), and
state is one of the following:
1—Power supply went from bad to good.
2—Power supply went from good to bad.
3—Power supply is not present.
In this example, the power supply in position 1 of cabinet 0 (main cabinet) went
from good to bad.
The Fourth Digit of the State Change Field (Fans)
The fourth digit of the state change field reports state changes in fans.
Example:
WARNING: -
Suncity HSG80 10020000000 HSG80 fans(0:A:2) (SP_MONITOR:
MonitorSubsys)
The fourth digit can have one of three values:
0—Everything is fine.
1—Fan state went from bad to good.
2—Fan state went from good to bad.
The position (in parentheses) of the fan follows, in the format:
cabinet_number:fan_position:state
where cabinet_number is the cabinet ID from 0 to 1, fan_position is the
position of the fan, and
state is either of the following:
1—Fan went from bad to good.
2—Fan went from good to bad.
In this example, a fan failure occurred in cabinet 0, the main cabinet.
The Fifth Digit of the State Change Field (Battery)
The fifth digit reports battery state change.
Example:
WARNING: -
Suncity HSG80 10002000000 HSG80 batt(6:fail) (SP_MONITOR:
MonitorSubsys)
The fifth digit can have one of three values: