HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
117HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
10. Disengage both retaining levers (see Figure 47), remove the controller, and
then place the controller in an antistatic bag or on a grounded antistatic mat.
Figure 47: Disengaging the controller retaining levers (dual-redundant
configuration shown)
Installing controllers in single-controller configurations
Perform the following steps to install a controller in a single-controller
configuration:
Caution: Carefully align the controller in the appropriate guide rails.
Misalignment can damage the backplane.
Note: Ensure that the program card is
not
installed in the controller.
1. Insert the replacement controller into controller A bay, and then engage the
retaining levers.
2. Connect a PC or terminal to the controller maintenance port.
3. Press and hold the Reset button while inserting the program card into the
controller.
1 Controller A
2 Controller retaining levers
3 Controller B
5036
1
2
3