HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
138 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
5. Restart the controller by pressing the Reset button.
Note: A controller restart can take as long as 60 seconds, indicated by the temporary
cycling of the port LEDs and a flashing Reset button.
Note: If the controller did not restart, use the following steps:
a. Press and hold the Reset button.
b. Reseat the controller program card.
c. Release the Reset button.
6. From the CLI prompt, display details about the configured controller by
entering the following command:
SHOW THIS_CONTROLLER FULL
7. Set the date and time by entering the following command:
SET THIS_CONTROLLER TIME=dd-mm-yyyy:hh:mm:ss
8. Mount the logical units on the host.
9. If using a Windows 2000 or Windows NT platform, restart the server.
10. Disconnect the PC or terminal from the controller maintenance port.
Replacing cache modules in dual-redundant controller configurations
This subsection describes how to remove or replace HSG60 and HSG80 cache
modules in dual-redundant controller configurations.
Caution: ESD can easily damage the cache module or a DIMM. Wear a
snug-fitting, grounded ESD wrist strap when completing controller cache
module removal and installation procedures.
Note: See Table 9 on page 121 for information on symbols used throughout these
instructions.