HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
173HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Note: The
VTDPY
display refreshes every ten seconds.
4. Press Ctrl+C and then enter the following command to exit VTDPY:
VTDPY> EXIT
5. Temporarily, move the PC or terminal to the maintenance port of controller B
to repeat step 2 through step 4 on controller B.
6. Return PC or terminal to the maintenance port of controller A.
7. If the controller is running in SCSI-2 mode and the Command Console LUN
(CCL) is enabled, you must disable the CCL prior to upgrading:
a. Determine if the controller is in SCSI-2 mode and the CCL is enabled by
entering the following command:
HSGA> SHOW THIS_CONTROLLER
Figure 71 shows only a portion of the resulting display—arrows point to
the pertinent status indication.
Figure 71: Screen display indicating SCSI version and CCL setting
b. If the controller is in SCSI-2 mode and the CCL is enabled, record the
status for restoration in step 35 on page 181.
c. Disable the CCL by entering the following command:
HSGA> SET THIS_CONTROLLER NOCOMMAND_CONSOLE_LUN
Controller:
HSG80 (C) DEC ZG80200258 Software V88S,
Hardware E01
NODE_ID = 5000-1FE1-0007-B780
ALLOCATION_CLASS = 1
SCSI_VERSION = SCSI-2
Configured for MULTIBUS_FAILOVER with ZG92810098
In dual-redundant configuration
Device Port SCSI address 7
Time: 14-Mar-2005 15:44:25
Command Console LUN is lun 0 (IDENTIFIER = 0)