HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
235HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
The Code Patch Main Menu is displayed (see Figure 116).
Figure 116: Code Patch Main Menu
9. Enter option 0.
10. Press the controller Reset button to restart the controller.
11. For dual-redundant controller configurations, repeat step 1 (on page 233)
through step 10 for the second controller.
Listing software patches
Use the following steps to list software patches:
1. Connect a PC or terminal to the controller maintenance port.
2. Start CLCP with the following command:
RUN CLCP
The Code Load & Patch local program Main Menu is displayed (see
Figure 117).
Figure 117: Code Load & Patch local program Main Menu
Code Patch Main Menu
0: Exit
1: Enter a Patch
2: Delete Patches
3: List Patches
Enter option number (0..3) [0] ?
Select an option from the following list:
Code Load & Patch local program Main Menu
0: Exit
1: Enter Controller Code LOAD utility
2: Enter Controller Code PATCH utility
3: Enter EMU Code LOAD utility
Enter option number (0..3) [0] ?