HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
90 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Figure 36: Display showing unit
Figure 37: Display showing the moved disk (not a member of the original RAIDset)
as part of the failedset
zBot> show d5
LUN Uses Used by
----------------------------------------------------------------------------
D5 R5
LUN ID: 6000-1FE1-0007-A220-0009-1040-2700-00A9
IDENTIFIER = 5
Switches:
RUN NOWRITE_PROTECT READ_CACHE
READAHEAD_CACHE WRITEBACK_CACHE
MAX_READ_CACHED_TRANSFER_SIZE = 32
MAX_WRITE_CACHED_TRANSFER_SIZE = 32
Access:
ALL
State:
ONLINE to this controller
Not reserved
NOPREFERRED_PATH
Size: 106643109 blocks
Geometry (C/H/S): ( 20993 / 20 / 254 )
zBot> show disk10300
Name Type Port Targ Lun Used by
----------------------------------------------------------------------------
DISK10300 disk 1 3 0 FAILEDSET
COMPAQ BF00963643 3B05
Switches:
NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED = 20MHZ (synchronous 20.00 MHZ negotiated)
Size: 17769177 blocks