HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)

FC Configuration Procedures
154 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
Note: This procedure assumes that the disks that you are adding to the spareset have
already been added to the controller's list of known devices.
To add the disk drive to the controller's spareset list, use the following syntax:
ADD SPARESET DISKNNNNN
Repeat this step for each disk drive you want to add to the spareset:
For example:
The following example shows the syntax for adding DISK11300 and DISK21300
to the spareset.
ADD SPARESET DISK11300
ADD SPARESET DISK21300
Removing a Disk Drive from the Spareset
You can delete disks in the spareset if you need to use them elsewhere in your
subsystem.
1. Show the contents of the spareset entering the following command:
SHOW SPARESET
2. Delete the desired disk drive entering the following command:
DELETE SPARESET DISKNNNNN
The RUN CONFIG command does not delete disks from the controllers’
device table if a disk has been physically removed or replaced. In this case,
you must use the command: DELETE DISKNNNNN.
3. Verify the contents of the spareset by entering the following command:
SHOW SPARESET
Enabling Autospare
With AUTOSPARE enabled on the failedset, any new disk drive that is inserted
into the PTL location of a failed disk drive is automatically initialized and placed
into the spareset. If initialization fails, the disk drive remains in the failedset until
you manually delete it from the failedset.
To enable autospare, use the following command:
SET FAILEDSET AUTOSPARE