HP StorageWorks Enterprise File Services WAN Accelerator 3.0.4 deployment guide (AG421-96001, March 2007)

30 2 - IN-PATH DEPLOYMENTS
On HP EFS WAN Accelerator B, specify HP EFS WAN Accelerator B as the
backup (other) and specify the in-path IP address of HP EFS WAN Accelerator
A as the master IP address.
Figure 2-7. Setup: Advanced Networking - Failover Settings Page
5. Under Automated Online Datastore Settings, click Enable Automated Online
Datastore Synchronization.
Select Master or Backup from the Current Appliance is the drop-down list.
Type a port number in the Synchronization Port text box. The default value is
7744.
Type the number of seconds in the Reconnection interval text box. The
default value is 30.
6. Type the backup HP EFS WAN Accelerator’s IP address in the Other Appliance’s
In-path IP Address text box.
7. Apply and save the new configuration in the Management Console.
8. Begin optimization.
9. View performance reports and system logs in the Management Console.