HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
100 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Disable Access to the Hosts at the Target Site
T To prevent the target host from writing to any remote copy set targets, disable access by
issuing the command:
SET UnitName DISABLE=ALL
Issue this command for each unit.
Note: This step is for remote copy set (RCS) LUNs only.
Additional Setup
T Reboot the host using the reboot -- -r command.
The format command does not now show any disks from the HSG80 subsystem.
Your Solaris host is now configured to use DRM. Follow this procedure for each Solaris host
present at the target site. After configuring the target site hosts, go to the section titled
Configure the Controllers at the Initiator Site” on page 100.
Configure the Controllers at the Initiator Site
Before you configure the controllers at the initiator site, be sure to:
Identify the WWN on the HBAs.
Select the name to assign to the initiator site. This name must be different from the one
you assigned to the target site.
To get your DT system up and running, you must set up and configure the controllers by
executing the following procedure.
I 1. Ensure that all enclosures, Fibre Channel switches, and power distribution units (PDUs),
are powered off.
I 2. Plug all rack PDU power cords into the main power receptacles.
I 3. Make sure that you have a serial connection ready to each of the controllers.
I 4. Power on all PDUs.
I 5. Ensure that the Fibre Channel switches are powered on, but not cabled.
I 6. Turn on the enclosures.
Note: When the enclosures are turned on, the controllers will boot only if the PCMCIA cards
are installed. If there are no cards in the controller slots, insert them now, and then press the
Reset button. For complete instructions on how to properly seat the controller cards, refer to the
HP StorageWorks HSG80 ACS Solution Software Version 8.7 Installation and Configuration
Guide
for your operating system.
I 7. Establish a CLI connection to the top controller. Refer to the HP StorageWorks HSG80
Array Controller ACS V8.7 Maintenance and Service Guide for instructions.