HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
109Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Example Display 33
LUN Uses Used by
------------------------------------------------------------------------
D10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISK1000
LUN ID: nnnn-nnnn-nnnn-nnnn-nnnn-nnnn-nnnn-nnnn
NOIDENTIFIER
Switches:
RUN . . . . . . . . . . . . . . . . . . . .NOWRITE_PROTECT READ_CACHE‘
READAHEAD_CACHE . . . . . . . . . . . . . . . . . . . .WRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 32
Access:
NONE
State:
ONLINE to this controller
Not reserved
PREFERRED_PATH = THIS
Host based logging NOT specified
Size: nnnnnnnn blocks
Geometry (C/H/S): ( 7000 / 20 / 254 )
.
Cable the Initiator Site
This section explains how to cable controllers and switches at the initiator site.
Connect Fiber Optic Cables Between Controllers and Fibre Channel Switches
Use your established cabling policy to connect the host to the Fibre Channel switch.
I 1. Make sure that you have installed all required GBICs into each of the Fibre Channel
switches.
I 2. Use 50-micron, multimode fiber optic cable to connect port 1 of the top controller to the
top Fibre Channel switch.
I 3. Use 50-micron, multimode fiber optic cable to connect port 2 of the top controller to the
top Fibre Channel switch.
I 4. Use 50-micron, multimode fiber optic cable to connect port 1 of the bottom controller to
the bottom Fibre Channel switch.
I 5. Use 50-micron, multimode fiber optic cable to connect port 2 of the bottom controller to
the bottom Fibre Channel switch.
Note: You should see an illuminated green LED on the switch as soon as the cable is inserted
at both ends. This verifies that there is a good connection.