HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
114 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Note: If you use scripting to automate failover and failback operations, do not use dashes
(hyphens) as separators in your naming convention—use underscores instead. Dashes are not
allowed by the Perl scripting language.
Repeat for each remote copy set.
You will see a confirmation message on your terminal, as shown in Example Display 34.
If the instance code on your screen matches the instance code in this example, you have
performed this command correctly.
Example Display 34
%EVL--Initra > --13-JAN-1946 05:01:56 (time not set)-- Instance Code: 0E010064
Template: 144.(90)
Power On Time: 0. Years, 36. Days, 6. Hours, 45. Minutes, 22. Seconds
Controller Model: HSG80
Serial Number: ZG8nnnnnnn Hardware Version: Enn(2B)
Software Version: V87P
Informational Report
Target Controller Board Serial Number: " ZG8nnnnnnn"
Initiator WWLID: nnnn-nnnn-nnnn-nnnn-nnnn-nnnn-nnnn-nnnn
Initiator Node Name: "BuildngA"
Initiator Unit Number: n.(nnnnnnnn)
Target WWLID: nnnn-nnnn-nnnn-nnnn-nnnn-nnnn-nnnn-nnnn
Target Node Name: "BuildngB"
Target Unit Number: n.(nnnnnnnn)
Remote Copy Set Name: "RCS1”
Instance Code: 0E010064
Set Failsafe at the Initiator Site (Optional)
When Failsafe mode is set and the remote copy set loses the target member, no further I/O is
allowed to the initiator member and an error is returned to the host. This is known as a failsafe
locked condition.
I 1. If you choose to set Failsafe mode, issue the following command:
SET RemoteCopyName ERROR_MODE=FAILSAFE
Example: Set rcs1 error_mode=failsafe
Note: When you set failsafe, all remote copy sets must be in a normal or normalizing state. If
remote copy sets are copying when you set failsafe, your command is rejected until the remote
copy sets return to normal mode.