HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
121Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
HP Tru64 UNIX
Before beginning this procedure, make sure that your host is up to date with service packs and
patches. For supported revision levels, refer to the DRM Release Notes.
Install the HBAs
I You must install at least two HBAs in each host system. Record the HBA WWID for use later
in this section. Refer to the Compaq StorageWorks 64-Bit PCI-to-Fibre Channel Host Bus
Adapter User Guide for installation instructions. The user guide is located at:
http://h18004.www1.hp.com/products/storageworks/techdoc/adapters/AA-RKPDB-TE.html.
Note: Do not attach your fiber connections to the HBAs until instructed to do so. The driver is
installed in the following step.
Install the HBA Driver
I The EMX driver for Tru64 UNIX is already installed. Issue the following command to verify
that the driver version and the firmware version are at supported levels:
# cat /usr/adm/messages lgrep KGPSA
You should see a display similar to that in Example Display 41.
Example Display 41
Apr 19 14:19:37 tru002 vmunix: KGPSA-CA : Driver Rev 1.30 :
F/W Rev 3.81A4(2.01A0): wwn 1000-0000-c924-fe8c
Multipath Software
I Tru64 UNIX has native multipath support with path auto-detection. No further configuration
is required.
Install SWCC (Optional)
I You may now install SWCC. For detailed information about SWCC, including installation,
refer to the Compaq StorageWorks Command Console Version 2.4 User Guide.
Connect the Host to the SAN
Use your established cabling policy to connect the host to the Fibre Channel switch.
I 1. Use 50-micron, multimode fiber optic cable to connect one adapter of each pair to the top
Fibre Channel switch.
I 2. Use 50-micron, multimode fiber optic cable to connect the other adapter of each pair to the
bottom Fibre Channel switch.
Example: If there are four adapters in a server, the first and third adapters must be
connected to the top Fibre Channel switch. The second and fourth adapters must be
connected to the bottom Fibre Channel switch.
I 3. Verify that the host has logged into the fabric:
SHOW CONNECTIONS