HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
123Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Example Display 43
Connection Unit
Name Operating system Controller Port Address Status Offset
HostA1 Tru64_UNIX THIS 1 210013 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn . . . . ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
HostA2 Tru64_UNIX OTHER 1 200013 online 0
HOST_ID=nnnn-nnnn-nnnn-nnnn . . . . ADAPTER_ID=nnnn-nnnn-nnnn-nnnn
Update Switch Zones
The switch zones created at the target site must be updated with the host connection
information (refer to Chapter 6, “Configuring the Optional Advanced DRM Solutions,” for
detailed information on zone creation):
I 1. On the top fabric, add the host connection to the zone that contains port 1 of the top
initiator controller.
I 2. On the bottom fabric, add the host connection to the zone that contains port 1 of the
bottom initiator controller.
Enable Access to the Hosts at the Initiator Site
I 1. The initiator units must have access to the hosts. Enable access with the following
command:
SET UnitName ENABLE_ACCESS_PATH=InitiatorHostConnectionNamex,
InitiatorHostConnectionNamey
Example: set UnitName enable_access_path=HostA1,HostA2
Note: There must be two paths per host. Repeat this sequence for each host.
I 2. From a terminal window on the host, issue the following commands to recognize the new
units and assign device special file numbers:
# hwmgr - scan comp - cat scsi_bus
# hwmgr - show scsi
Your Tru64 UNIX host is now configured to use DRM. Follow this procedure for each Tru64
UNIX host present at the initiator site. After configuring the initiator site hosts, go to the
section titled “Additional Host Configuration,” on page 144.
HP-UX
Before starting this procedure, make sure that your host is up to date with service packs and
patches. For supported revision levels, refer to the DRM Release Notes.