HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
128 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
I 5. Load Secure Path for IBM Fibre Channel driver:
a. Load the Secure Path CD into the CD drive.
b. Enter the following commands:
#mkdir /mnt
#mount -v cdrfs -r /dev/cd0 /mnt
#mkdir /tmp/driver
#cp /mnt/driver/PC1000SP.image /tmp/driver
#cd /tmp/driver
#installp -acd PC1000SP.image all
#lslpp -l PC1000.driver.obj
#umount /mnt
Note: Follow the vendor documentation if using the PC2000 HBA.
I 6. Run Configuration Manager to add Fibre Channel HBA to the configuration database.
Enter the following commands:
#cfgmgr -v
#lsdev -Cc adapter
I 7. Connect fiber cables to HBAs.
I 8. Run Configuration Manager to add hdisks / HSG80 Raid Array to the configuration
database. Enter the following commands:
#cfgmgr -v
#lsdev -Cc disk
The system will find HSG80 Raid Array devices at this time. If CCL is enabled on the
HSG80 the server will find a Command Console LUN.
Multiple instances of the Command Console LUN hdisks may be displayed. Remove all
of the higher numbered hdisks, keeping only the lowest numbered hdisk of the Command
Console LUN. Remove the hdisks with the following command:
#rmdev -dl hdiskx
where x is the number of the hdisk to be removed.
I 9. Run the HP StorageWorks Install Agent, if required:
#cd /usr/stgwks2
# ./stgwks_aix.sh
Choose Option 1.
I 10. Create Volume Groups, Logical Volumes, and Files Systems.
I 11. Configure clustering services (if required).
I 12. Check the status of the HBAs periodically.