HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
129Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Upgrade Installation
If you are currently using an AIX server in transparent failover mode, and you wish to upgrade
to ACS Version 8.7P in a DRM environment, follow these instructions.
Upgrade Installation Assumptions
All components are connected
AIX OS is upgraded to v4.3.3 or v5.1
Cambex Fibre Channel adapters are installed
A version of Secure Path is loaded
A version of the solution platform kit is loaded, or has been upgraded
HSG80 ACS code is being upgraded to v8.7P
Storage subsystem is pre-configured with or without a CCL LUN, in SCSI-2 or SCSI-3
mode, with the LUN connection type set as WINNT
HBAs are installed in pairs
Volume groups, logical volumes, and file systems created
Clustering services may be installed
HBA Limitations
HBAs have the following limitations:
Addressing of LUNS is limited to 16 devices. This limitation must be considered when
planning the subsystem storage configuration.
Configuring a CCL LUN will leave 15 LUN addresses.
Installation Steps
I 1. Stop all I/O.
I 2. Stop clustering services (if running).
I 3. Stop the HP StorageWorks Agent (if running).
I 4. Backup all Volume Groups (highly recommended).
I 5. Unmount and perform file system check on all logical volumes, varyoff, and export
volume groups, with the following commands:
#umount /dev/(logical_volume_name)
#fsck /(file_system_name)
#varyoffvg (volume_group_name)
I 6. Remove all hdisks associated with DEC HSG80 RAID array from the configuration
database with the following commands:
#lsdev -Cc disk
#rmdev -dl hdiskx (x is the hdisk number)
I 7. Remove all Fibre Channel adapters from the configuration database with the following
commands:
#lsdev -Cc adapter
#rmdev -dl scsix
(x is the Cambex adapter number)