HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
131Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
b. Enter the following commands:
#mkdir /mnt
#mount -v cdrfs -r /dev/cd0 /mnt
#mkdir /tmp/driver
#cp /mnt/driver/PC1000SP.image /tmp/driver
#cd /tmp/driver
#installp -acd PC1000SP.image all
#lslpp -l PC1000.driver.obj
#umount /mnt
I 16. Run Configuration Manger to add Fibre Channel HBA to the configuration
database with the following commands:
#cfgmgr -v
#lsdev -Cc adapter
I 17. Connect fiber cables to HBAs.
I 18. Run Configuration Manager to add hdisks or HSG80 Raid Array to the
configuration database with the following commands:
#cfgmgr -v
#lsdev -Cc disk
The system will find HSG80 Raid Array devices at this time. If CCL is enabled on the
HSG80 the server will find a Command Console LUN.
Multiple instances of the Command Console LUN hdisks may be displayed. Remove all of
the higher numbered hdisks, keeping only the lowest numbered hdisk of the Command
Console LUN. Remove the hdisks with the following command:
#rmdev -dl hdiskx
where x is the number of the hdisk to be removed.
I 19. Run the HP StorageWorks Install Agent, if required:
#cd /usr/stgwks2
# ./stgwks_aix.sh
Choose Option 1.
I 20. Re-establish volume groups, logical volumes, and files systems with the following
commands:
#varyonvg (volume_group_name)
#mount /dev/(logical_volume__name)
I 21. Reestablish clustering services (if required).
I 22. Check the status of the HBAs periodically.