HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
146 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
PORT_2_TOPOLOGY = FABRIC (fabric up)
Address = 220313
REMOTE_COPY = BuildngA
Cache:
256 megabyte write cache, version 0012
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
256 megabyte write cache, version 0012
Cache is GOOD
No unflushed data in cache
Battery:
NOUPS
FULLY CHARGED
Expires:
Extended information:
Terminal speed 9600 baud, eight bit, no parity, 1 stop bit
Operation control: 00000000 Security state code: 75184
Configuration backup disabled
IT 2. To see the information for all association sets known to the controller pair, issue the
following CLI command:
SHOW ASSOCIATIONS FULL
You should see a display similar to that in Example Display 53 for each association set.
Example Display 53
Name Association Uses Used by
-----------------------------------------------------------------------
AS1 association RC1
RC2
RC3
Switches:
NOFAIL_ALL
NOORDER_ALL
NOLOG_UNIT
IT 3. To see information for all remote copy sets known to the controller pair, issue the
following CLI command:
SHOW REMOTE_COPY_SETS FULL
You should see a display similar to that in Example Display 54 for each remote copy set.