HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
147Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Example Display 54
Name Uses Used by
-----------------------------------------------------------------------
RC1 remote copy D1 AS1
Reported LUN ID: 6000-1FE1-0001-3AE0-0009-9141-6136-0038
Switches:
OPERATION_MODE = SYNCHRONOUS
ERROR_MODE = NORMAL
FAILOVER_MODE = MANUAL
OUTSTANDING_IOS = 60
Initiator (BuildngA\D1)
State:
ONLINE to this controller
Target state:
BuildngB\D1 is NORMAL
IT 4. To see information for all units configured to the controller, issue the following CLI
command:
SHOW UNITS FULL
You should see a display similar to that in Example Display 55 for each unit.
Example Display 55
D2 DISK10100 BuildngA\RC2
LUN ID: 6000-1FE1-0001-3AE0-0009-9141-6136-0045
NOIDENTIFIER
Switches:
RUN NOWRITE_PROTECT READ_CACHE
READAHEAD_CACHE WRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 1
Access:
BuildngBA,BuildngBB,BuildngBC,BuildngBD,HOSTA1,HOSTA2
State:
ONLINE to this controller
Not reserved
PREFERRED_PATH = OTHER_CONTROLLER
Host based logging NOT specified
Target NORMAL
Size: 17769177 blocks
Geometry (C/H/S): ( 5258 / 20 / 169 )
IT 5. To see the connection name, operating system, controller, controller port, adapter ID
address, online or offline status, and unit offset, issue the following CLI command:
SHOW CONNECTIONS