HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring the Optional Entry-Level DRM Solutions
153Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Figure 23: Single-switch DRM configuration
Setting Up the Single-Switch Configuration
Before making any connections with the fiber optic cable, create and enable the zones that
simulate two fabrics. As Figure 23 shows, the Red Zone uses ports 0 through 7; the Blue Zone
uses ports 8 through 15.
Note: This configuration uses only multimode, 50-micron fiber optic cable and is, therefore, limited
to 500 meters for any one connection.
This procedure is a variation of the procedure provided in Chapter 4. To set up the
single-switch configuration:
1. Install all required GBICs into the Fibre Channel switch, with half of the GBICs in each
zone.
2. Make the following controller connections:
a. Connect a fiber optic cable from port 1 of the top controller of Controller Pair A to
port 1 of the Fibre Channel switch.
b. Connect a fiber optic cable from port 2 of the top controller of Controller Pair A to
port 3 of the Fibre Channel switch.
c. Connect a fiber optic cable from port 1 of the bottom controller of Controller Pair A to
port 11 of the Fibre Channel switch.
d. Connect a fiber optic cable from port 2 of the bottom controller of Controller Pair A to
port 9 of the Fibre Channel switch.
Host A
Controller
Pair A
Controller
Pair Y
Switch
Host Y
CXO7736A
141220
131197531 15
Red Zone Blue Zone