HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Troubleshooting
168 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Step 4: Issue switchShow Command from the First Switch
Issue a SWITCHSHOW command at the switch prompt to see the port connections:
sw11:admin> switchShow
Table 12 shows typical output from the SWITCHSHOW command and highlights the
information relevant to troubleshooting.
Note: WWIDs that start with 10:00 or 20:00 are HBAs. WWIDs that start with 50:00 are
controllers or controller ports. WWIDs that start with 60:00 are LUNs.
Table 12: First switchShow Command Output
Command Output Comments
switchName: sw11 Name of the switch
switchType: 2.4
switchState: online
switchRole: Principal
switchDomain: 1 Domain
switchId: fffc41
switchWwn: 10:00:00:60:69:10:47:69 WWID
port 0: sw Online F-Port 10:00:00:00:c9:20:c9:f0 WWIDs that start with 10:00 are HBAs.
port 1: -- No_Module
port 2: -- No_Module
port 3: -- No_Module
port 4: -- No_Light Check for a bad GBIC or cable.
port 5: -- No_Module
port 6: -- No_Module
port 7: -- No_Module
port 8: -- No_Module
port 9: -- No_Module
port 10: -- No_Module
port 11: -- No_Module
port 12: -- No_Module
port 13: sw Online F-Port 50:00:1f:00:07:20:9d:e1 Cabled to port 1 of the bottom controller.
port 14: sw Online F-Port 50:00:1f:00:07:20:9d:e2 Cabled to port 2 of the bottom controller.
port 15: sw Online
E-Port10:00:00:60:69:00:54:65
sw12” (downstream)
ISL—always on E-Port.