HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Troubleshooting
170 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Note: This switch is named sw13, which also has a domain of 1. We recommend that each switch
have a unique domain within the fabric. We recommend unique names even across fabrics.
Figure 28 is a picture of the cabling information we have gathered so far. The cabling
information added to Figure 28 is drawn from Table 13, which shows that:
Port 0 of sw13 (where we issued the SWITCHSHOW command) is cabled to the HBA
whose WWID ends in -F21A.
Port 4 of sw13 is cabled to port 1 of the top controller at the same site.
Port 5 of sw13 is cabled to port 2 of the top controller at the same site.
Port 6 of sw13 is cabled via an ISL to sw14.
Table 13: Second switchShow Command Output
switchName: sw13
switchType: 2.4
switchState: o
nline
switchRole: Subordinate
switchDomain: 1
switchId: fffc41
switchWwn: 10:00:00:60:69:00:51:5a
port 0: sw Online F-Port 10:00:00:00:c9:21:f2:1a
port 1: -- No_Module
port 2: -- No_Module
port 3: -- No_Module
port 4: -- sw Online F-Port 50:00:1f:e1:00:07:9d:d3
port 5: -- sw Online F-Port 50:00:1f:e1:00:07:9d:d4
port 6: -- sw Online E-Port 10:00:00:60:69:00:57:0a “sw14” (upstream)
port 7: -- No_Module
port 8: -- No_Module
port 9: -- No_Module
port 10: -- No_Module
port 11: -- No_Module
port 12: -- No_Module
port 13: -- No_Module
port 14: -- No_Module
port 15: -- No_Module
value = 16 = 0x10