HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Troubleshooting
175Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Information from the Operating Systems
Figure 30 shows both fabrics (two sets of switches that communicate), but we do not yet know
which HBAs go to which servers.
Figure 30: Fourth cabling diagram
Step 8: Associating HBAs with Servers
Our ability to associate HBAs with servers (without removing the adapter from the server and
reading the label) depends on operating system and platform type. The following sections
provide procedures for determining the server WWIDs for each operating system.
HP OpenVMS
Shut down the system and use the console WWID manager to issue the following commands:
>>> Set mode diag
POO
>>> wwidmgr –adapter kgpsa0
POO
>>> wwidmgr –adapter kgpsa1
Repeat for each server.
Port 1
Bottom controller
-9DD1
Port 2
Bottom controller
-9DD2
046
5
Switch "SW13"
Domain 1
046
5
Switch "SW14"
Domain 0
046
7
Switch "SW12"
Domain 0
014
13 15
Switch "SW11"
Domain 1
Port 1
Top controller
-9DD3
Port 2
Top controller
-9DD4
Port 1
Bottom controller
-9DE1
Port 2
Bottom controller
-9DE2
Port 1
Top controller
-9DE3
Port 2
Top controller
-9DE4
HBA . . .F251 HBA . . .F21A HBA . . .C9F0 HBA . . .C9E1
CXO7655A