HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Zoning in the Storage Area Network
204 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
9. Save the configuration:
cfgSave
This completes alias naming for the Brown Zones.
Note: The Red Zones have already been created, so the port aliases for the Red Zone ports do not
need to be repeated.
Create the Zone Names
1. Select the Telnet session from switch A.
2. Create the Yellow Zone_Top name and add the zone numbers:
zoneCreate “Yellow Zone_Top”, Host 3_A; Controller A1-top”
3. Create the Brown Zone_Top name and add the zone numbers:
zoneCreate “Brown Zone_Top”, “Host 4_Y; Controller Y1_top”
Note: Red Zone_Top has already been created and does not need to be repeated.
These two steps created the zone names that are stored in flash memory in both switches A
and Y. The next step is to repeat these two commands for switches B and Z.
4. Save the configuration:
cfgSave
5. Select the Telnet session from Switch B.
6. Create the Yellow Zone_Bottom name and add the zone numbers:
zoneCreate “Yellow Zone_Bottom”, “Host 3_B; Controller A1_Bottom
7. Create the Brown Zone_Bottom name and add the zone numbers:
zoneCreate “Brown Zone_Bottom”, “Host 4_Z; Controller Y1_Bottom
Note: “Red Zone_Bottom” has already been created and does not need to be repeated.
These two steps created the zone names that are stored in flash memory in both switches B
and Z.
8. Save the configuration:
cfgSave
Add the New Zones to the Configuration
1. Select the Telnet session from switch A.
2. Add the new top zones to the configuration Top_Fabric: