HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Zoning in the Storage Area Network
206 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
1,4
alias: Controller Y2_top
1,6
alias: Host 1_A
0,2
alias: Host 2_Y
1,2
alias: Host 3_A
0,8
alias: Host 4_Y
1,8
Effective configuration:
cfg: Top_Fabric
zone: Blue Zone_Top
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,2
1,4
zone: Brown Zone_Top
1,8
1,4
zone: Green Zone_Top
0,2
0,4
zone: Red Zone_Top
0,6
1,6
zone: Yellow Zone_Top
0,8
0,4
7. Select the Telnet session from switch B.
8. Add the new bottom zones to the configuration Bottom_Fabric:
Note: The Bottom_Fabric has already been created.
This adds Yellow Zone_Bottom and Brown Zone_Bottom to a configuration file titled
“Bottom_Fabric,” which already contains Green Zone_Bottom, Blue Zone_Bottom, Red
Zone_Bottom, and their alias members. These are stored in flash memory for switches B
and Z.
9. Save the configuration:
cfgSave
10. Enable the new zone configuration:
cfgEnable “Bottom_Fabric”