HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Status Comparison
214 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Example Display 3
Name Uses Used by
-----------------------------------------------------------------------
RC1 remote copy D1 AS1
Reported LUN ID: nnnnnnnnnnnnnnn
Switches:
OPERATION_MODE = SYNCHRONOUS
ERROR_MODE = NORMAL
FAILOVER_MODE = MANUAL
OUTSTANDING_IOS = 60
.
.
.
Example Display 4 corresponds to step 4 of the “Issuing SHOW Commands” section:
Example Display 4
D2 DISK10100 BuildingB\RC2
LUN ID: nnnnnnnnnnnnnnnnnnnnnn
NOIDENTIFIER
Switches:
RUN NOWRITE_PROTECT READ_CACHE
READAHEAD_CACHE WRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 1
Access:
BuildngAA, BuildngAB, BuildngAC, BuildngAD, HostCon_1, HostCon_2
State:
ONLINE to this controller
Not reserved
PREFERRED_PATH = OTHER_CONTROLLER
Target NORMAL
Size: 17769177 blocks
Geometry (C/H/S): ( 5258 / 20 / 169 )
Example Display 5 corresponds to step 5 of the “Issuing SHOW Commands” section:
Example Display 5
Connection Unit
Name Operating system Controller Port Address Status
Offset !NEWCON28 WINNT THIS 1 634000 OL this 0
HOST_ID=1000-0000-C921-4B5B ADAPTER_ID=1000-0000-C921-4B5B.