HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Upgrading to ACS Version 8.7P Software
226 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
I 9. Shut down Controller B:
HSGA> SHUTDOWN OTHER_CONTROLLER
Note: Disregard any messages about misconfigured controllers or failover status.
After Controller B shuts down, the Reset button and the first three LEDs turn on (see Figure 38).
Proceed only after the Reset button stops flashing and remains on.
Figure 38: Controller reset button and first three LEDs
I 10. Verify that all units failed over to Controller A:
HSGA> SHOW UNITS FULL
The following text is only a portion of the resulting display:
I 11. Upgrade the software on Controller B by performing the following steps:
Note: After this step has been performed, the previous ACS version cannot be restored to this
subsystem without performing the downgrade process, which should be performed only by HP
authorized service personnel.
a. Remove the program card ESD cover from Controller B.
b. While pressing and holding the controller Reset button, eject the old program card.
c. After ejecting the program card, release the Reset button.
d. While pressing and holding the controller Reset button, insert the new program card.
e. After the card is fully inserted, release the button. Controller B restarts.
1 Reset button
2 First three LEDs
123456
CXO6991A
2
1
State:
ONLINE to this controller
Not reserved