HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Upgrading to ACS Version 8.7P Software
230 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Note: After this step has been performed, the previous ACS version cannot be restored to this
subsystem without performing the downgrade process, which should be performed only by HP
authorized service personnel.
a. Remove the program card ESD cover from Controller B.
b. While pressing and holding the controller Reset button, eject the old program card.
c. After ejecting the program card, release the Reset button.
d. While pressing and holding the controller Reset button, insert the new program card.
e. After the card is fully inserted, release the button. Controller B restarts.
Note: A controller restart can take as long as 60 seconds and is indicated by the
temporary cycling of the port LEDs and a flashing Reset button. Disregard messages about
misconfigured controllers or failover status. When controller B has restarted, it
automatically shuts down Controller A.
f. Install the program card ESD cover on Controller B.
T 12. After Controller B restarts, verify that Controller B completed initialization:
a. Connect the PC or terminal to the maintenance port of Controller B.
b. Make sure that the CLI prompt for Controller B appears.
Note: Wait for the CLI prompt before proceeding.
c. Verify that controller A is shut down; the Reset button and the first three LEDs turn
on (see Figure 38 on page 226). Proceed only after the Reset button stops flashing and
remains on.
T 13. Upgrade the software on controller A by performing the following steps:
a. Remove the program card ESD cover from Controller A.
b. While pressing and holding the controller Reset button, eject the old program card.
c. After ejecting the program card, release the Reset button.
d. While pressing and holding the controller Reset button, insert the new program card.
e. After the card is fully inserted, release the button. Controller A restarts.
Note: A controller restart can take as long as 60 seconds and is indicated by the
temporary cycling of the port LEDs and a flashing Reset button. Disregard messages about
misconfigured controllers or failover status.
f. Install the program card ESD cover on Controller A.