HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Getting Started
47Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
2. Ping using the name of the switch. This verifies the operation of the name resolution.
3. Telnet into the switch (username = admin; password = password [default setting]). Refer to
your switch documentation for Telnet session procedures. Make the following adjustments
to the switch:
—Enter
switchName to configure the switch name. Be sure to designate a name that
enables you to easily identify the switch you are trying to access.
Example:
switchName NewSwitchName
—Enter switchShow to reveal the status of the switch and some of its ports.
—Enter
version to display the firmware levels. For updated version information, go to
the DRM Release Notes.
4. Using a Java-capable browser, go to
http://<FC switch DNS name> to view a visual
representation of the switch. (You need to know the Domain Server Name.) You can
double-click this picture for further information.
For procedures related to the other switch families (C-series and M-series), refer to the
appropriate vendor documentation.
Setting Up the Fiber Optic Cables
Before you connect the fiber optic cables to your subsystems, it is important to understand the
designated names of each component. See Table 5 on page 49 for an overview list of required
connections for each site and between the sites.
Note: For instructions on making connections, refer to Chapter 4, “Configuring a Standard Data
Replication Manager Solution
.”
Figure 12 shows how each component is referenced in this document.
Figure 12: Locations and names of components for connecting fiber optic lines
Before you connect the fiber optic cables, HP recommends that you tag each end of the cables
with the following information.
CXO7096A
Port 1,
Controller A
Port 2,
Controller A
Port 1,
Controller B
Port 2,
Controller B
Top FC Switch
Bottom FC Switch
Redundant PDU