HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Getting Started
51Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
5. Change to SCSI-3 mode by issuing the following CLI command:
SET THIS_CONTROLLER SCSI_VERSION=SCSI-3
You should see a display similar to that in Example Display 3.
Example Display 3
BuildngATop> set this_controller scsi_version=scsi-3
Warning 4030: Any units that would appear as unit 0 to a host will not be
available when in SCSI-3 mode
Warning 4020: A restart of both this and the other controller is required
before all the parameters modified will take effect
%CER--BuildngATop> --01-APR-2002 14:11:00-- Restart of this controller required
%CER--BuildngATop> --01-APR-2002 14:11:01-- Restart of the other controller-
required
Restart of this controller required
Restart of the other controller required
6. Issue the following restart CLI commands:
RESTART OTHER_CONTROLLER
RESTART THIS_CONTROLLER
7. When both controllers are restarted, verify that the HSG80 controllers are in SCSI-3 mode
by issuing the following CLI command:
SHOW THIS_CONTROLLER
You should see a display similar to that in Example Display 4.
Example Display 4
Controller:
HSG80 ZG84906303 Software ACS 8.7P-0, Hardware E12
NODE_ID = 5000-1FE1-0000-01F0
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Configured for MULTIBUS_FAILOVER with ZG84906237
In dual-redundant configuration
Device Port SCSI address 7
Time: 02-APR-2002 14:24:21
Command Console LUN is lun 0 (NOIDENTIFIER)
Host Connection Table is LOCKED
Smart Error Eject Disabled
.
.
.
8. Repeat steps 1 through 7 at the other site's HSG80 controller pair.
9. Enable access to HSG80 devices using the method for your OS type.