HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
62 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Configure the Controllers at the Target Site
Note: Target site procedure steps are marked with a target symbol, T. Initiator site procedures are
marked with an initiator symbol,
I.
Before configuring the controllers at the target site, follow these preparatory steps:
T 1. Identify the World Wide Name (WWN) on the HBAs in each host.
T 2. Establish the names to assign to the target and initiator sites. Use a naming convention that
is meaningful, like building or city names; for example, name the initiator site BuildngA
and target site BuildngB.
Note: These names may be a maximum of nine characters. They may consist of alphanumeric
characters and special characters, except for the comma ( , ) and
backslash ( \ ).
If you use scripting to automate failover and failback operations, do not use dashes (hyphens)
as separators in your naming convention—use underscores instead. Dashes are not allowed by
the Perl scripting language.
To get your DT system up and running, you must set up and configure the controllers. These
tasks are outlined in the following procedure:
T 1. Ensure that all enclosures, Fibre Channel switches, and power distribution units (PDUs)
are powered off.
T 2. Plug all rack PDU power cords into the main power receptacles.
T 3. Make sure that you have a serial connection ready to the maintenance port of each
controller. Refer to the HP StorageWorks HSG80 Array Controller ACS V8.7
Maintenance and Service Guide for instructions.
T 4. Power on all PDUs.
T 5. Ensure that the Fibre Channel switches are powered on, but not cabled.
Note: When the enclosures are turned on, the controllers start only if the PCMCIA cards are
already installed. If there are no cards in the controller slots, insert them now and press the
Reset button. Refer to the
HP StorageWorks HSG80 Array Controller ACS V8.7 Maintenance
and Service Guide
for complete instructions on properly seating the controller firmware cards.
T 6. Turn on the enclosures.
T 7. Establish a CLI connection to the bottom controller. Refer to the HP StorageWorks
HSG80 Array Controller ACS V8.7 Maintenance and Service Guide for instructions.
T 8. Verify that the bottom controller is on and functional by looking for the CLI prompt on the
maintenance port.